  Datasheet File OCR Text:
  specification lps-100-3.3 lps-100-5 lps-100-7.5 lps-100-12 lps-100-13.5 lps-100-1 5 LPS-100-24 lps-100-27 lps-100-48 model dc voltage rated current current range rated power output voltage adj. range line regulation load regulation setup, rise time hold up time (typ.) voltage range frequency range efficiency(typ.) input inrush current (typ.) leakage current working humidity working temp. storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload over voltage ac current (typ.) 3.3v 5v 7.5v 12v 13.5v 24v 27v 48v 20a 20a 13.3a 8.4a 7.5a 6.7a 4.2a 3.8a 2.1a 0 ~ 20a 0 ~ 20a 0 ~ 13.3a 0 ~ 8.4a 0 ~ 7.5a 0 ~ 6.7a 0 ~ 4.2a(6a 10s) 100.8w(144w 10s) 0 ~ 3.8a 0 ~ 2.1a 66w 100w 99.75w 100.8w 101.25w 100.5w 102.6w 100.8w 150mvp-p 100mvp-p 100mvp-p 100mvp-p 100mvp-p 100mvp-p 150 mvp-p 150mvp-p 200mvp-p 3 ~ 3.6v 4.5 ~ 5.7v 6 ~ 9v 10 ~ 13.2v 12 ~ 15v 13.5 ~ 18v 20 ~ 26.4v 26 ~ 32v 41 ~ 56v 3.0% 3.0% 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 2.0% 2.0% 1.5% 1.5% 1.5% 1.5% 0.5% 0.5% 0.5% 800ms, 50ms/230vac 1200ms, 50ms/115vac at full load 20ms/230vac 20ms/115vac at full load 88 ~ 132vac / 176 ~ 264vac auto switch 248 ~ 370vdc 47 ~ 63hz 69% 77% 77% 79% 79% 80% 80% 81% 81% 2.3a/115vac 1.5a/230vac cold start 30a/115vac 60a/230vac <1ma / 240vac 105 ~ 140% (+24v: above 6.5a) rated output power 3.8 ~ 4.45v 5.75 ~ 6.75v 9.4 ~ 10.9v 13.8 ~ 16.2v 15.5 ~ 18.2v 18 ~ 21v 27.6 ~ 32.4v 3 3.7 ~ 39.2v 57.6 ~ 67.2v protection type : hiccup mode, recovers automatically after fault co ndition is removed protection type : hiccup mode, recovers automatically after fault co ndition is removed 20 ~ 90% rh non-condensing -10 ~ +60 (refer to output load derating curve) -20 ~ +85 , 10 ~ 95% rh 0.05%/ (0 ~ 50 10 ~ 500hz, 2g 10min./1cycle, period for 60min. each along x, y, z axes 203.6khrs min. mil-hdbk-217f (25 ) 222*62*32mm (l*w*h) 0.45kg; 24pcs/12.5kg/1.39cuft file name:lps-100-spec 2011-02-14 safety standards harmonic current ems immunity ul60950-1, tuv en60950-1 approved compliance to en55022 (cispr22) class b compliance to en61000-3-2,-3 compliance to en61000-4-2,3,4,5,6,11, light industry level, cr iteria a 100w single output without pfc function l p s - 1 0 0 s e r i e s universal ac input / full range protections: short circuit / overload / over voltage cooling by free air convection 100% full load burn-in test fix switching frequency at 134khz 2 years warranty features : emi conduction & radiation environment safety & emc (note 4) protection ripple & noise (max.) note.2 voltage tolerance note.3 withstand voltage isolation resistance i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 5. if the input range 85v-89v, the output load is changed from 0a-rated load, t here will be reduced 20v for 1second (LPS-100-24). 6. mounting holes m1 and m2 should be grounded for emi purposes. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) 15v
derating curve file name:lps-100-spec 2011-02-14 unit:mm fosc : 135khz 60 80 100 120 140 160 180 200 220 240 260 +12v +12v 300 13 250 12 200 11 150 10 100 9 50 8 25 7 ta=25 dc output connector (cn2) : jst b8p-vh or equivalent pin no. 1,2,3,4 5,6,7,8 assignment +v -v mating housing jst vhr or equivalent terminal jst svh-21t-p1.1 or equivalent ac input connector (cn1) : jst b5p-vh or equivalent pin no. 1 2,4 5 3 assignment ac/l fg ac/n no pin mating housing jst vhr jst svh-21t-p1.1 or equivalent or equivalent terminal 5 5 cn1 62 52 32 13 2 ac fuse f4a/250v fs1 5 4 fg +v adj. 4- 3.5 1 2 3 4 5 8 6 7 cn2 222 212 -10 0 10 20 30 40 50 60 20 40 60 80 100 convection (3.3v,7.5v~48v) lps-100-5v 18 cfm min forced air ambient temperature ( ) input voltage (v) 60hz load (%) output voltage (v) output ripple (mvp-p) (horizontal) block diagram mechanical specification static characteristics (12v) o.v.p. control -v +v rectifiers & filter switching power filter & rectifiers o.l.p. detection circuit pwm fg i/p filter emi 115/230vac auto switch 3max. 100w single output without pfc function l p s - 1 0 0 s e r i e s


▲Up To Search▲   

 
Price & Availability of LPS-100-24

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X